Indocyanine Green Fluorescence Imaging To Predict Graft Survival After Orthotopic Liver Transplantation: A Pilot Study

ABSTRACT Introduction: The incidence of primary non-function (PNF) after liver transplantation (LT) remains a major concern with the increasing use of marginal grafts. Indocyanine green (ICG) fluorescence is an imaging technique used in hepatobiliary surgery and LT. Because few early predictors are available, we aimed to quantify in real time the fluorescence of grafts during LT…

Visualization And Quantification Of Anastomotic Perfusion In Colorectal Surgery Using Near-Infrared Fluorescence

ABSTRACT Background Anastomotic leakage (AL) is one of the most troublesome complications in colorectal surgery. Recently, near-infrared fluorescence (NIRF) imaging has been used intraoperatively to detect sentinel lymph nodes and visualize the blood supply at the region of interest (ROI). The aim of this study was to evaluate the role of visualization and quantification of…

SGM-101: An Innovative Near-Infrared Dye-Antibody Conjugate That Targets CEA For Fluorescence-Guided Surgery.

Abstract PURPOSE: Fluorescence-guided surgery (FGS) provides surgeons with new opportunities to improve real-time cancer nodule detection and tumor margin visualization. Currently, the most important challenge in this field is the development of fluorescent dyes that specifically target tumors. We developed, characterized and evaluated SGM-101, an innovative antibody-dye conjugate in which the fluorochrome BM104, which has…

Randomized Controlled Trial Comparing White Light With Near-Infrared Autofluorescence For Parathyroid Gland Identification During Total Thyroidectomy

Abstract BACKGROUND: Parathyroid glands are difficult to identify during total thyroidectomies, and accidental resection can lead to problematic postoperative hypocalcemia. Our main goals were to evaluate the effectiveness of using near-infrared light (NIRL) autofluorescence intraoperatively for parathyroid gland identification and to measure its impact on postoperative hypocalcemia incidence. STUDY DESIGN: Total thyroidectomies were performed on…

Randomized Trial Of Near-Infrared Incisionless Fluorescent Cholangiography

Abstract Background: Incisionless near-infrared fluorescent cholangiography (NIFC) is emerging as a promising tool to enhance the visualization of extrahepatic biliary structures during laparoscopic cholecystectomies. Methods: We conducted a single-blind, randomized, 2-arm trial comparing the efficacy of NIFC (n = 321) versus white light (WL) alone (n = 318) during laparoscopic cholecystectomy. Using the KARL STORZ Image1 S imaging system with OPAL1 technology…